Life Touch Water Proofing
One Call can solve
Your Leakage Problems

+91 9990265151, 9990275151

Our Service

1

2

3

4

5

Our rich industry experience, backed up by expert team and diligent workforce we offer our valued clients all kinds of waterproofing services and solutions. We followed the globally accepted waterproofing standard while treating a particular area. Sometimes different waterproofing systems & solutions are applicable even in same area because of surface, locations, weather conditions and vibrations. Hence, our services are imparted by our experts to meet the specified requirements of our valued patrons.The basic process of our services for the treatmentsthat we generally followed for various waterproofing problems are describe below:

BASEMENT RAFT WATERPROOFING

In this service, we clean the PCC surface and remove loosely adhering particles (if any) after then, we followed the following sequence of operations:

  • Proving and laying of PMM admixed with Acrylic Polymer Emulsion.
  • Applying of compatible primer coat for bonding with substrates.
  • Sealing of all joints, Corners, Junctions of pipes and masonry with PMM/ EM.
  • Application of waterproofing system. The selection of WP system is depending on various aspects such as location, category of WC, layers etc.
  • Protection of treatment with CMP enriched with IWC 2% to 4% by weight of cement.
  • Providing and fixing required dia MS/PVC/GI nozzles embedded about the half of the depth of the member to be grouted in grid pattern at spacing approx. 1.0Mtr C/c while casting the raft slab.(The caps shall be fixed in the mouth of the nozzles to avoid chocking while concreting or nozzle can also be fixed after concreting).
  • Injection of cementitious slurry admixed with grouting compound into the nozzles with grouting pumps.
  • Grouting operation will be done after the raft/slab concrete reached the full strength i.e. 28 days after casting of concrete.
  • Sealing off the nozzles with quick setting sealing compound or PMM after cutting of the projected nozzles over the concrete surface.

RETAINING WALL WATERPROOFING

In this service, we clean and scrub the surface with wire brush and water wash to get rid of loose debris from the surface including exposing of cracks, gaps, pits, holes etc (if any) after then, we followed the following sequence of operations:

  • Cutting/Chipping of CJ in “U” Shaped groove of approx. 20mm wide x 20mm deep and area around Tie Holes closing approx. 50mm x 50mm x 25 using chipping tools and then filling the same with PMM after applying a slurry coat.
  • Injection grouting of the wall from inner side in grid pattern at a distance @1.0Mtr C/c at CJ and 1.5 Mtr C/c on other areas.
  • Fuse coat of the surface after thoroughly cleaning, smoothing etc. complete in all respect.
  • Application of waterproofing system. The selection of WP system is depending on various aspects such as location, category of WC, layers etc.
  • Providing of CM protection plaster to protect damages to well applied waterproofing system from landscaping works.

BASEMENT DECK/NON-TOWER/PODIUM AREA WATERPROOFING

In this service, we clean and scrub the RCC slab with wire brush and water wash to get rid of loose debris from the surface including exposing of cracks, gaps, pits, holes, etc (if any) after then, we adopt the following process:

  • Providing and doing waterproofing treatment by non-shrink expanding cementitious pressure grouting process along the construction joints with required dia MS/PVC/GI nozzles of minimum 25mm deep @ 0.75 C/c along the construction joints.
  • Injecting of cement slurries of different viscosities by grouting pressure by pump using non-shrink grout mixed with neat cement slurry.
  • Sealing of nozzles after the injection operation with non-shrink fast setting polymer compound.
  • Removing and repairing of surface imperfections, protrusions, cracks, structurally unsound and loose concrete using PMM.
  • Sealing and filling of all pipe joints with epoxy mortar or PMM.
  • Making a fillet of 50x50mm at the horizontal and vertical junction using CM admixed with acrylic polymer emulsion.
  • Providing and applying of Elastomeric Waterproofing System over the cleaned, dry and oil & grease free surface with brush/roller. Applying of REWC and SRBWC with the reinforcement glass fibre mesh between the coats to give more strength to waterproofing system. Final coat of acrylic polymer waterproof coating to act as a binder with cementitious mortar. All the layers should be applied in perpendicular direction to each other. This waterproofing system should be applied upto deck finish level.
  • Laying of protection CC screed with M15 G of minimum 50mm thickness in required slope after laying of non-woven geotextile fabric over waterproofing layer.
  • Providing and laying of high strength polypropylene modular drain cells having good compressive strength for subsurface drainage including providing and laying of needle punched non-woven polyester GFC over drain cell.

SWIMMING POOL WATERPROOFING

In this service, we clean the surface with wire brush to get rid of loose material/ laitance / debris from the surface including exposing of cracks, gaps, pits, holes, etc (if any) after then, we followed the following steps:

  • Providing of injection grouting at construction joints with cement slurry modified with non-shrink grouting compound, dosage as per requirement or recommendation.
  • Preparation of joints/ corners and sealing of pipe junctions with PMM/Epoxy mortar/Polyurethane Sealants.
  • Applying a bond coat of SBR based polymer coating after saturating the surface with water curing.
  • Providing and applying of highly flexible acrylic based polymer waterproofing coating in with or without FGC. The layers are decided as per requirement or recommendation.
  • Protection of treatment with CMP enriched with IWC confirming to IS: 2645 including curing.

PLANTER WATERPROOFING

In this service, we clean and scrub the surface with wire brush and water wash to get rid of loose debris from the surface including exposing of cracks, gaps, pits, holes etc (if any) after opening of brick grooves by horizontally and vertically (for post WP) after then, we followed the following operations:

  • Filling /building up of grooves with PMM after a slurry coat of SBR based polymer.
  • Compatible primer coat on surface after smoothing the surface.
  • Highly flexible coatings of waterproof polymer with FG for interlocking and monolithic structure.
  • Protection of treatment with minimum 50mm thick CC Screed & CMP admixed with IWC.
  • Filling of planter soil as per requirement over after providing and laying of Nano drain/Stone aggregate with GFC separation media.

LIFT PITS WATERPROOFING

In this service, we clean and scrub the surface with wire brush and water wash to get rid of loose debris from the surface including exposing of cracks, gaps, pits, holes etc (if any) after then, we followed the following process:

  • Injection grouting of the surface at a distance @ 1.0Mtr C/c with CS/Polyurethane grouting.
  • Filling up/ building up the cracks, gaps, pits, holes etc with PMM/ EM.
  • Deep impregnation compatible primer coat for bonding with substrates.
  • Application of waterproofing system. The selection of WP system is depending on various aspects such as locations, category of WC, layers etc.
  • Protection of treatment with CMP enriched with IWC.

WATER TANK WATERPROOFING (UG/OH)

In this service, we clean and scrub the surface with wire brush to get rid of loose debris from the surface including exposing of cracks, gaps, pits, holes, crevices etc (if any)after then, we adopt the following process:

  • Cutting/chipping of grooves in “U” Shaped at the BCJ and CJ and filling of the grooves with flexible polymeric compound.
  • Injection grouting of the wall from inner side in grid pattern at a distance @ 1.0Mtr C/ c at CJ and 1.5 Mtr C/c on other areas.
  • Compatible primer coat of the surface which is absolute vapour permeable after complete preparation of surface.
  • Application of highly flexible waterproof membraneous coating on entire primer treated areas.
  • Protection of treatment with CMP/Tiles or Food Grade Coating.

TOILETS & KITCHEN WATERPROOFING

In this service, we clean and scrub the surface with wire brush and water wash to get rid of loose debris from the surface including exposing of cracks, gaps, pits, holes etc (if any) after then, we adopt the following process:

  • Opening of brick grooves by horizontally and vertically. (for post waterproofing application)
  • Sealing and filling of all corner joints, pipe junctions with flexible polymeric compound/ EM
  • Filling /building up of grooves with PMM after a coat of SBR based polymer.
  • Compatible primer coat on surface after smoothing the surface.
  • Application of acrylic based flexible waterproof polymer coatings.
  • Protection of treatment with CMP enriched with IWC confirming to IS: 2645.
  • Filling of light weight concrete/ khangar upto required surface level.

TERRACE WATERPROOFING

In this service, we clean and scrub the surface with wire brush and water wash to get rid of loose debris from the surface including exposing of cracks, gaps, pits, holes etc (if any) after then, we followed the following sequence of operations:

  • Filling up/ building up the cracks, gaps, pits, holes etc with flexible polymeric compound.
  • Deep impregnation compatible primer coat for bonding with substrates.
  • Application of waterproofing system. The selection of WP system is depending on various aspects such as location, category of WC, layers etc. after well examine of site.
  • Protection of treatment with minimum 50mm thick CC Screed/CMP to protect from mechanical damages.

TERRACE GARDEN WATERPROOFING

In this service, we clean the surface with wire brush and water jet wash to get rid of loose material/ laitance / debris from the surface and before installing of waterproofing system we ensure that the surface is now perfect to receive the system and it is free from contaminants such as fungus, algae, dust, etc. after then, we followed the following sequence of operations:

  • Providing of injection grouting at construction joints with non-shrink expanding cement slurry/Epoxy injection resin system.
  • Filling of the surface cracks with PMM after cutting/chipping in “U” Shaped groove using chipping tools and sealing of live cracks with PU Sealant (if any).
  • Application of highly flexible waterproof membraneous coating over entire surface including parapet wall with or without FGC.
  • Providing and laying of protection CC screed of M25 G of minimum 50mm thick in required slope over well applied waterproofing system.
  • Application of anti-biological growth coating over cured concrete surface.
  • Making gola/watta at all the corner joints with CM enriched with IWC after applying of a slurry coat.
  • Providing and laying draincell with non-woven geotextile cloth.
  • Filling of garden soil upto required level.

This waterproofing methodology is applicable on those concrete terraces which are specially designed for terrace gardens.

ASBESTOS/MS SHED WATERPROOFING

In this service, we clean and scrub the surface after removing and repairing of old waterproofing membrane, broken sheets or any other foreign materials (if any)before installing of waterproofing systems after then we followed the following sequence of operations:

  • Specially treating of overlapping joints.
  • Compatible primer coat of the surface after repairing of cracks, holes etc. (if any)
  • Waterproof cum heat reflective coatings with FGC. The selection of WP system is depending on various aspects such as location, category of WC, layers etc. after well examine of site

POLYESTER MONOLITHIC GLASSMESH WATERPROOF LINING (FOR MS GUTTER ETC.)

In this service, we clean and scrub the metal surface after removing of tarfelts (if any) before installing of waterproofing systems after then, we followed the following sequence of operations:

  • Applying coat of de-rusting agents.
  • Repairing of holes, cracks, joints etc. with epoxy or polyester resin and unsaturated glassmesh.
  • Laying of glassmesh of specified GSM impregnated with reactive chemical combination.
  • Hard coat of the surface with polyester chemical mix with pigment of choice.

CANOPY

In this service, we clean and scrub the surface after removing of rubbles (if any) before installing of waterproofing systems after then, we followed the following sequence of operations:

  • Water wash of the surface with brush application to obtain clean and moist surface.
  • Primer coat of the surface with soft set vapour permeable crystalline polymeric compound.
  • Filling and repairing of cracks, holes, crevices, joints etc. with high strength flexible vapour permeable crystalline mortar paste after applying a coat of elastomeric waterproof coating.
  • Applying a coat of HGMP polymer non-shrink filler based compound for permanent film forming.
  • Impregnation of the FGC with HGMP polymeric compound in crosswise directions.
  • Making chemical bond gola/watta at all the corner joints.
  • Chemical bond CMP in slope for protection and fast discharged of water.

EXPANSION JOINT TREATMENT

In this service, we clean and scrub the EJ mouth edges surface with wire brush to get rid of loose debris from surface after then, we followed the following process:

  • Preparation of EJ mouth edges and surface with PMM/ready to use repair mortar, if there is any damages and un-proper gap.
  • Applying of epoxy bonding adhesive after applying of masking tape.
  • Providing and fixing of waterproof flexible tape.
  • Applying one more layer of adhesive to interlock the tape.
  • CM/RMM of required thickness to be laid to protect from abrasion after sealing of overlapping joints.
  • Protection of whole expansion joint system with plate of required size which is suitable for expansion and contraction. (The selection of plate is depending on various aspects such as locations, thickness, strength, colors etc.)

For more information on work specifications in details and rates on any of the above treatment for your site can be obtained only after physical inspections of the actual site by our experts only.

Our Address
B-531, 1st Floor, Nehru Ground NIT,
Faridabad-121001 (Haryana), India
Contact No.
+91-9990265151, 9990275151
(0129)-4039151, 2416051


Lifetouch Water Proofing